Tennis Centre Banner Image

Lighting Case Study
Tennis centre

Tennis Centre PDF

Overview

Kellwood Lighting were tasked with upgrading Bisham Abbey’s Indoor Tennis Courts. Bisham Abbey is a national sports centre with world class facilities catering for the country’s leading athletes.

Objectives

  • Supply and install lighting to meet ATP and Sport England standards.
  • A system compatible with the facility’s Hawk-Eye ball tracking camera system.
  • A robust solution to minimise maintenance costs and site down time.
  • Emergency lighting to comply with BS 5266 Part 1.

Project Specifications

In this project Kellwood were tasked to meet Class 1 international standards for an indoor sports tennis centre;


ParameterTarget
Horizontal Illuminance>750 lux
Uniformity of Illuminance>0.7
Glare<50
CRI>80
CCT>4000K



In order to meet the requirements outlined by CIBSE and the LTA, light had to be directed to the appropriate playing areas. Through the use of 60° optics, the light output was directed away from absorbent surfaces (screening and architectural walls) and towards the centre of each court.

Rotating lights in their stainless steel brackets by 15° increased the uniformity on the playing area. CAD simulations demonstrated that this also permitted a glare-free observation area for coaches between courts.

  • Tennis Centre Gallery Image

Design & Specification

Kellwood Lighting's designs demonstrated the 140W Drummond 3 Series was the right
product for the job:

Lumen Output
Using carefully designed optics and Nichia chips the Drummond 3 series provides up to 138lm/W. This resulted in average lux levels of >1000lux for each court.

Impact Protection
A solid aluminium enclosure and modular design gives the Drummond Series resistance to tennis ball strikes.

Environmental Temperatures, Operating Hours and Lumen Maintenance (TM21 Calculated L90B10>160,000hrs) were assessed to ensure designs included an application-specific Maintenance Factor.

Uniformity of Illuminance
To meet Class 1 specifications for indoor courts >0.7 uniformity is required. Uniformity >0.7 throughout the tennis hall was achieved.

Glare
One of the stipulations for this project was to have <50 glare across all courts. This was achieve through using 60° and 90° optics.

Marine Resistant surface-finishes and stainless steel fixings (saltspray tested in accordance with ISO9227:2012), and an IP67 rating, protects the product and the investment




Glare
One of the stipulations for this project was to have <50 glare across all courts. This was achieve through using 60° and 90° optics.

Marine Resistant surface-finishes and stainless steel fixings (saltspray tested in accordance with ISO9227:2012), and an IP67 rating, protects the product and the investment.


Hawkeye

Our Drummond 3 Series proved to be the best solution. Its integral Philips Xitanium driver provides a stable constant current to the LED array, mitigates flicker, and ensured compatibility with the camera system.

Game. Set. Match. Kellwood

Latest
Blog Posts

Our lights are used by

BookerBrewdogSantanderDupontGlenfiddichSparLogoplasteLogainairNHSLothian BusesWabtecWalkers
Customer Reviews Bg
  • I am delighted to have used Kellwood...

    - P. Nisbet, Wabtec Corporation

  • a project that was well planned and promptly accomplished

    - E. McHugh, Loganair

  • Where others let us down, Kellwood did not

    W. Coley, Barking Abbey School

  • ...my client is over the moon with the end results

    A. Fraser, MacLean Electrical

  • I'd certainly recommend them

    V. Richardson, Stolle Europe

  • I'm more than pleased with the guys. I'd recommend them to anyone

    G. Gray, Logoplaste

RecolightScottish Engineering